Engineering model, modified-rev 6, unit has updated board installed-RP282 to RP583, dynamic eq bias/channel tracking within +/-2dB, assymetrical RMS/detector circuit installed, logarithmic slope detection, PS modifications/head room and noise mod. Calibrated +/- 1db channel to channel. Too much to list, call for details.